Newest RIGOL DS1072U 70Mhz Oscilloscope 500MSa/s FFT warranty air shipping track

Newest RIGOL DS1072U 70Mhz Oscilloscope 500MSa/s FFT warranty air shipping track

Newest RIGOL DS1072U 70Mhz Oscilloscope 500MSa/s FFT warranty air shipping track
New RIGOL DS1072U 70Mhz, 500M Sa/s Portable Oscilloscope 2 chs. DS1000U series is a kind of economical digital oscilloscope with high-performance. The front panel of DS1000U series comes with clear visual design, conforming to the usage of. Traditional instruments, which is convenient for the users. Electronic circuit test 2. Circuit function test 3. Logical relation between signals verification 4. Circuit of mixed signal test 5. Easy to use design. Built-in help menu enables information getting more convenient. Multiple Language User Interface, support English input. Support U disk and local files storage. Waveform intensity of analog channel can be adjusted. To display a waveform automatically by. Pop-up menu makes it easy to operate. 500MSa/s real-time sample rate and 10GSa/s equivalent sample rate 2. 5.6 inch and 64k TFT LCD make waveform display more clear and vivid 3. Abundant trigger types: Edge, Pulse Width, Video, Slope and Alternate 4. Unique adjustable trigger sensitivity enables to meet different demands 5. Enable to measure 22 types of waveform parameters and track measurements via cursor automatically 6. Unique waveform record and replay 7. Fined delayed scan function 8. Built-in FFT function, hold practical digital filters 9. Pass/Fail detection function enables to output testing results 10. Math operation available to multiple waveforms 11. Powerful PC application software UltraScope 12. Standard configuration interface: USB device, USB Host, R232 and support U disk storage and PictBridge print standards 13. Unique Key Lock function meets the needs of industrial production 14. Support remote command control. Specifications All specifications apply to DS1000U series digital oscilloscopes unless where noted. To come up to these specifications, two conditions must be met firstly: The instrument must have been operated continuously for 30 minutes under specified operating temperature. Do perform Self-Calibration operation through Utility menu if the range of operating temperature variations up to or more than 5°C. Note: all specifications are guaranteed unless where marked typical. DS1000U series oscilloscopes contain abundant triggers: Edge trigger, Pulse Width trigger, Video trigger, Slope trigger and Alternate trigger. Unique function of adjustable trigger sensitivity is good for filtering possible noise from trigger signal to avoid false triggers. RIGOL provides powerful PC application software UltraScope. UltraScope enables to capture and measure waveform, perform local and remote operation, save waveforms as. Bmp format, save files as. Xls format and print waveforms. Waveform recording of DS1000U series oscilloscopes not only can record. Input waveforms from two channels, but also can record the waveforms. Outputted by Pass/Fail testing. Totally, up to 1000 frames of waveforms are. Besides, users can analyze waveforms according to. Playback or save function to get more exact datum. In cursor mode, users can easily measure by moving cursor. 3 types of cursor measurement are optional: Auto, Manual and Track. 512K Memory depth Alternate Trigger. Lower noise Keyboard locker. The Pass/Fail function monitors the changes of signals by comparing. Whether the input signal is within the pre-defined mask. Result not only can be displayed on screen or output by isolated Pass/Fail. Port, but also can be alarmed according to turn on system sound. Automatically Measure 22 Waveform Parameters. Oscilloscopes provide 22 types of waveform parameters for automatically. Measuring, which contains 10 Voltage and 12 Time parameters. The waveform will be displayed one time while all channels finish N times sample. N could be selectable from 2, 4, 8, 16, 32, 64, 128 and 256. 1M±2%, the input capacitance is18pF±3pF. 1X, 5X, 10X, 50X, 100X, 500X, 1000X. 400V DC+AC peak value. 1 M input impedance. 40V (DC+AC peak value). Time delay between channel (typical). Real-time: 13.65Sa/s 500MSa/s. Equivalent: 13.65Sa/s 10MSa/s. Scanning speed range (s/div). Sample rate and delay time accuracy. ±50ppm (any interval 1ms). Measurement accuracy (full bandwidth). Single: ± (1 sample interval+50ppm×reading+0.6ns). >16 averages: ± (1 sample interval+ 50ppm×reading+0.4ns). 8-bit resolution, two channels sample simultaneously. 2mV/div10V/div (at input terminal BNC). Maximum input voltage on analog channel. CAT 300Vrms, 1000Vpk; instaneous overvoltage1000Vpk. RP2200 10:1: CAT 300Vrms. RP3200 10:1: CAT 300Vrms. RP3300 10:1: CAT 300Vrms. Selectable analog bandwidth limit (typical). Low frequency response (AC coupling, -3dB). Rise time (when equivalent sample, typical at BNC). 2mV/div5mV/div, ±4% (in normal or average acquisition mode). 10mV/div10V/div, ±3% (in normal or average acquisition mode). DC measurement accuracy (average acquisition mode). When vertical displacement is zero and N16. ± (DC gain accuracy× reading+0.1div+1mV). When vertical displacement is not zero and N16. ± [DC gain accuracy × (reading + vertical displacement) + (0.1%×vertical displacement) + 0.2div]. From 2mV/div to 245mV/div, add 2mV for setting value. From 250mV/div to 10V/div, add 50mV for setting value. Voltage difference measurement precision. In the same setting and condition, voltage difference (V) between any two points in the waveforms coming from the average of more than 16 waveforms have been acquired: ± (DC gain accuracy×reading+0.05div). 0.1div1.0div (adjustable). ±6div from center of screen. Trigger level accuracy (typical) applicable to signal of rising and falling time. ±0.3div ×. V/div (±4div from center of screen). ±(6% setting value+200mV). In normal mode: pre-trigger memory depth/(2×sample rate) delayed trigger 1s. In slow scan mode: pre-trigger 6div, delayed trigger 6div. Set level to 50% (typical). When input signal frequency 50Hz. Rising, falling and rising+falling. (>, <, =) positive pulse width, (>, <, =) negative pulse width. Support for standard NTSC, PAL and SECAM broadcast systems. Line number range: 1525 (NTSC) and 1625 (PAL/SECAM). (>, <, =) positive slope, (>, <, =) negative slope. Edge, pulse width, video and slope. Voltage difference between cursors V. Time difference between cursors. Voltage and time value for waveform points. Cursors are visible for automatic measurement. Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, overshoot, preshoot, freq, period, rise time, fall time, +pulse width, -pulse width, +duty, -duty, delay. 145mm (5.6 inch) diagonal TFT liquid crystal display. 320 horizontal × RGB × 234 vertical pixels. Approximately 3Vpp, peak to peak value. 2A, T level, 250V. Below 35°C: 90% relative humidity. 35°C40°C: 60% relative humidity. Operating at 3,000m or below. Non-operating at 15,000m or below. 1 Power cord for your country. 2 Two units of original RP2200 150Mhz probes. 4 Free BNC test lead. The item "Newest RIGOL DS1072U 70Mhz Oscilloscope 500MSa/s FFT warranty air shipping track" is in sale since Wednesday, November 21, 2012. This item is in the category "Industrial\Test, Measurement & Inspection\Analysers & Data Acquisition\Oscilloscopes & Vectorscopes". The seller is "smtzone" and is located in shenzhen. This item can be shipped worldwide.
  • Brand: RIGOL
  • MPN: DS1072U

Newest RIGOL DS1072U 70Mhz Oscilloscope 500MSa/s FFT warranty air shipping track
This entry was posted in newest and tagged , , , , , , , , . Bookmark the permalink.